Update the configuration of a device.
https://production-connect.blacklinesafety.com/1/configuration/:id
id required |
The id of the device.
Example Value: 555 |
network_timeout optional |
The period (in minutes) that a device must communicate before it is considered offline (min: 0, max: 60).
Default Value: 15 |
fall_detection_enabled optional |
The fall detection enabled flag.
Default Value: true |
no_motion_enabled optional |
The no motion enabled flag.
Default Value: true |
no_motion_timeout optional |
The number of minutes of no motion before an alarm is triggered (min: 1, max:30).
Default Value: 5 |
manual_checkin_enabled optional |
The manual check in enabled flag.
Default Value: false |
manual_checkin_timeout optional |
The timeout in minutes for a manual check in (min: 1, max: 180).
Default Value: 60 |
motion_sensitivity optional |
The sensitivity of the motion detector in percent, where 100% detects the most motion (min: 0, max: 100).
Default Value: 50 |
silent_alarm_enabled optional |
The silent alarm enabled flag.
Default Value: true |
emergency_alarm_enabled optional |
The emergency alarm enabled flag.
Default Value: true |
visual_alarm_enabled optional |
The visual alarm enabled flag. This is to enable/disable the lights on the FDU.
Default Value: true |
use_gps_as_motion optional |
The use GPS as motion flag. This is useful if traveling in a vehicle (no motion is picked up but are considered moving).
Default Value: true |
gps_motion_cutoff_speed optional |
The cutoff speed for using GPS as motion in Km/hr. Speed greater than the cutoff is considered motion (min: 20, max:255)
Default Value: 25 |
alarm_acknowledge_timeout optional |
The amount of time in seconds the user has to acknowledge an alarm before it becomes an alert (min: 30, max: 240).
Default Value: 30 |
gsm_lost_alarm_timeout optional |
The timeout in minutes before sending an alert after GSM has been lost (min: 1, max: 30).
Default Value: 5 |
low_battery_alarm_level optional |
The battery level, in percent, at which a low battery alert is generated. Must be an increment of 10% and 0% is the equivalent of off (min:0, max:100).
Default Value: 20 |
gsm_lost_alarm_enabled optional |
The GSM lost alarm enabled flag.
Default Value: false |
language optional |
The language of the device.
Must be one of:
|
fdu_required optional |
The FDU required flag.
Default Value: false |
checkin_on_fdu_motion optional |
The check in on FDU motion flag.
Default Value: true |
gps_publish_period optional |
This is the period in minutes which Loner Mobile send locations to the server (min:0, max:60, 0 = disabled).
Default Value: 15 |
automatic_shutdown_threshold optional |
The battery percentage in which the device shuts down. Must be an increment of 10% and 0% is the equivalent of off (min:0, max:100).
Default Value: 0 (off) |
alarm_sound_enabled optional |
Is the alarm sound enabled.
Default Value: true |
alarm_vibration_enabled optional |
Is the alarm vibration enabled.
Default Value: true |
PUT | https://production-connect.blacklinesafety.com/1/configuration/555?access_token=abcd |
{
"network_timeout": 15,
"fdu":{
"fall_detection_enabled": true,
"no_motion_enabled": false,
"no_motion_timeout": 10,
"manual_checkin_enabled": false,
"manual_checkin_timeout": 10,
"motion_sensitivity": 80,
"silent_alarm_enabled": false,
"emergency_alarm_enabled": true,
"visual_alarm_enabled": true,
"use_gps_as_motion": false,
"gps_motion_cutoff_speed": 25,
"alarm_acknowledge_timeout": 30,
"gsm_lost_alarm_timeout": 5,
"low_battery_alarm_level": 30,
"gsm_lost_alarm_enabled": false
},
"mobile":{
"language":"english",
"fdu_required":false,
"checkin_on_fdu_motion":true,
"gps_publish_period":15,
"automatic_shutdown_threshold":0,
"alarm_sound_enabled":true,
"alarm_vibration_enabled":true
}
}
No response data is sent on a successful PUT.